Semi-conductor technology makes YELLOW JACKET monitoring systems an attractive alternative to electrochemical or infrared systems.

Control panel and sensors now ordered separately!

  • FEATURES
    • Controllers and sensors mount to any flat vertical surface
    • For point detection, mount sensor(s) near the most likely leak source
    • For perimeter detection, sensors surround the potential leak area
    • Operating temperature range of -20 to 122ºF (-29 to 50ºC). 
    • Factory calibrated sensors available for R-11, R-1234yf, R-134a, R-22, R-245fa, R-404A, R-407C, R-410A and R-507A (call factory for other refrigerants)
    • Should not be used with refrigerants that have an Occupational Exposure Limit of less than 300 ppm
    • For use in the following environments
      • Refrigerant storage areas
      • Supermarkets
      • Refrigeration machinery rooms
      • Cold storage facilities
      • Walk-in coolers
      • Marine and fishing fleets
      • Delis, ice cream parlors or quick service stores
  • SPECS
    • Controller: 7.6″ x 4″ x 3″ (193 mm x 102 mm x 76 mm), 2.8 lbs. (1.3 kg)
    • Relays: Dry contact switch; 10 amp at 120/250V max
    • Sensor: 4.3″ x 2.2″ x 0.9″ (109 mm x 56 mm x 23 mm) Sensors can be hard wired up to 200′ from controller
    • Power LED: Green
    • Alarm: 80 dB at 3′ (92 cm)
    • Sensor cable: Use 4 conductor, unshielded cable, 22 AWG or larger (0.25″ O.D. maximum)*
    • Power: 120V/60 Hz, 230V/50-60 Hz or 12VDC
    • Operation: Constant power-on and fault monitoring
    • Reset: Automatic on low level; manual on high level

    *check your local building code for additional requirements specific to your application.

  • DOCUMENTS
  • UPCs

    UPC#

    Description

    Control Panels (order sensors separately)

    68201

    (120V) – Single sensor control panel with two levels of detection

    68231

    (230V) – Single sensor control panel with two levels of detection

    68202

    (120V) – Two sensor control panel with two levels of detection

    68232

    (230V) – Two sensor control panel with two levels of detection

    68212

    (12V) – Two sensor control panel with two levels of detection

    Sensors (order control panels separately)

    68188

    R-407C Refrigerant sensor for two levels of detection

    68189

    R-410A Refrigerant sensor for two levels of detection

    68190

    R-507A Refrigerant sensor for two levels of detection

    68192

    R-22 Refrigerant sensor for two levels of detection

    68195

    R-134a Refrigerant sensor for two levels of detection

    68196

    R-1234yf Refrigerant sensor for two levels of detection

    68197

    R-245fa Refrigerant sensor for two levels of detection

    68198

    R-11 Refrigerant sensor for two levels of detection

    68091

    R-404A Refrigerant sensor for two levels of detection

    68099

    Monitor key switch set